Environmental Performance:

  1. Heat Resistance
    1. Testing Method: Use Constant Temperature And Humidity Test Instrument or
      Aging Testing Equipment (Oven).
      Temperature: 85˚C, Time: 96 Hours.
    2. Testing Result: Pass 7.2, 7.3
  2. Heat Cycle Testing
    1. Testing Method: Use Constant Temperature And Humidity Testing Equipment
      Testing Condition:
      -40˚C(4Hours)-›+25˚C(1Hour)-›+85˚C(4Hours)-›+25˚C(1Hour)
      Total 5 Cycles
    2. Testing Result: Pass 7.2, 7.3
  3. Moisture Resistance
    1. Testing Method: Use Constant Temperature and Humidity Testing Equipment
      Testing Condition:
      Temperature 40˚C, Humidity 95%RH, Placed Time 96 Hours.
    2. Testing Result: Pass Electrical performance.2, Electrical performance.3